Motor Test Facility Specifications |
|
If your application requires speed, torque or power ratings outside the posted ranges, please contact Magtrol. We will do our best to find a solution for your motor testing needs. |
|
Motor Testing Capabilities: |
- Torque range from 0.018 N·m to 56.50 N·m
- Speeds up to 30,000 rpm
|
|
Ratings of Dynamometers in Test Lab: |
|
Dynamometer
Model |
Maximum
Torque
Range |
Maximum Power |
Maximum Speed |
5 Minute |
Continuous |
watts |
watts |
rpm |
HD-106-5N |
0.018 N·m |
35 |
7 |
30,000 |
HD-100-5N |
0.080 N·m |
75 |
20 |
25,000 |
HD-400-5N |
0.280 N·m |
200 |
55 |
25,000 |
HD-510-5N |
0.850 N·m |
750 |
375 |
25,000 |
HD-515-5N |
1.700 N·m |
1,500 |
900 |
25,000 |
HD-710-5N |
3.100 N·m |
1,500 |
935 |
25,000 |
HD-715-5N |
6.200 N·m |
3,360 |
2,985 |
25,000 |
HD-810-5N |
14.000 N·m |
3,510 |
3,000 |
12,000 |
HD-815-5N |
28.000 N·m |
7,025 |
6,000 |
12,000 |
HD-825-5N |
56.500 N·m |
14,000 |
12,000 |
8,000 |
|
|
|
Motor Testing Facility Power: |
- 0-480 V @ 50 A max, 60 Hz - single-phase and
three-phase
- 480-575 V @ 40 A max, 60 Hz - single-phase
and three-phase
|
- DC Power:
- 0-30 V, 330 A max.
- 0-50 V, 20 A max.
|
|
|